DiversiTech, 7-CRNR35, Dual Element Fuse, 35 A, 250 V, 200,000 A

$9.79
- +
In stock
1 Available At My Branch
53 Available At All US Supply Locations
Brand
DiversiTech
Part Number
7-CRNR35
SKU
1896269

Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse

The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.

Engineered for System Longevity and Compliance

This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.

Key Technical Advantages

  • Amperage Rating: 35 A
  • Voltage Rating: 250 VAC
  • Interrupting Rating: 200,000 A RMS Symmetrical
  • Construction: Dual element, time delay
  • Class: RK5 per UL 248-12

Performance Features

  • Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
  • RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
  • High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
  • Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.

Installation Considerations

Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.

Contractor Use Cases

For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.

Compliance and Standards

  • UL Listed: UL 248-12, Class RK5
  • CSA Certified: CSA C22.2 No. 248.12

Professional Summary

The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.

Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse

The DiversiTech® 7-CRNR35 is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.

Engineered for System Longevity and Compliance

This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.

Key Technical Advantages

  • Amperage Rating: 35 A
  • Voltage Rating: 250 VAC
  • Interrupting Rating: 200,000 A RMS Symmetrical
  • Construction: Dual element, time delay
  • Class: RK5 per UL 248-12

Performance Features

  • Dual Element Time Delay – Allows temporary overloads typical of motor startups without compromising protection.
  • RK5 Certification – Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
  • High Interrupt Capacity – Rated for 200kA to safely isolate high fault currents.
  • Consistent Arc-Quenching – Reduces potential damage to downstream components in fault scenarios.

Installation Considerations

Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.

Contractor Use Cases

For licensed HVAC and electrical contractors: The 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.

Compliance and Standards

  • UL Listed: UL 248-12, Class RK5
  • CSA Certified: CSA C22.2 No. 248.12

Professional Summary

The DiversiTech® 7-CRNR35 Dual Element Time Delay Fuse is an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.

Specifications

Specifications
Weight 0.200000
Height 3
Length 0.75
Width 0.75
Item Type Fuse
Brand DiversiTech
Interrupt Rating 200,000 A
MPN 7-CRNR35
Amperage Rating 35 A
Item Returns This item can be returned