Oil Burner Primary Control with 15 Second Pre-Purge and 15 Second Post-Purge, Replaces R7184P Relay Controls

$104.18
- +
In stock
0 Available At My Branch
4 Available At All US Supply Locations

Brand
Beckett
Part Number
7505P 1515
SKU
1904190
Manufacturer
Beckett

Details

Beckett GeniSys Burner Control, Advanced, Series: 7505, 102 to 132 VAC, 100 mA, Interrupted/Intermittent Duty Ignition, -40 to150 degree F

The Beckett GeniSys Advanced Burner Control is a 120 VAC primary safety control for residential and light commercial oil burners used inch boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time.

Specifications

Specifications
SKU1904190
Weight1.150000
Ignition TypeInterrupted/Intermittent Duty
Item ReturnsThis item can be returned
Features

Features

  • Thermostat and boiler control compatible
  • Moisture: 5 to 95% RH, non-condensing and non-crystallizing
  • Igniter: 120 VAC, 3 A at 0.7 PF min
  • 0.1 A thermostat anticipator current
  • 24 VAC thermostat voltage
  • Motor: 120 VAC, 10 full load amps (FLA), 60 locked rotor amps (LRA)
  • Solenoid valve: 120 VAC, 1 A at 0.7 PF min
  • 15 sec valve-on delay time
  • 15 sec motor-off delay time
  • Customizable pre-time and post-time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Technician pump prime mode
  • 15 sec lockout time
  • 60 Hz frequency