2-1/4" x 12" x 6" Register Boot, Center End
MPN
RB102126
SKU
2010790
$7.15
In stock
43 Available At All US Supply Locations

Lukjan
View All Lukjan products
Lukjan Center End Register Boot — Series P17C, 6″ Ø, 12″ Length, 2-1/4″ Width
Center-end style HVAC register boot that transitions airflow from a 6-inch round duct to a narrow rectangular throat. Ideal for installations where the duct terminates flush with a surface and the grille or register will mount directly to a narrow face opening.
- Series / model: P17C (Lukjan) :contentReference[oaicite:1]{index=1}
- Part number / MPN: RB102126 for the 2-1/4″ × 12″ × 6″ variant :contentReference[oaicite:2]{index=2}
- Nominal duct connection: 6 inch diameter (round duct) :contentReference[oaicite:3]{index=3}
- Boot length (depth): 12 inches :contentReference[oaicite:4]{index=4}
- Throat / face opening width: 2-1/4 inches (2.25″) :contentReference[oaicite:5]{index=5}
- Material: Galvanized steel, 30 gauge :contentReference[oaicite:6]{index=6}
- Finish: Hot-dip galvanized :contentReference[oaicite:7]{index=7}
- Weight (approx): 0.50 lb :contentReference[oaicite:8]{index=8}
- Mounting orientation: Center end — air flows into the round duct end, and discharges through a rectangular face (narrow side) :contentReference[oaicite:9]{index=9}
- Seam / connection method: Screwed or riveted, sealed with foil tape or duct mastic at joints for air-tightness (standard practice for HVAC register boots)
- Compatibility considerations:
- Ensure the grille / register faceplate opening is long enough to cover throat length and at least as wide as 2.25″.
- Check that airflow velocity and pressure drop through the narrow throat are acceptable for your system design.
- Seal all seams and joints to prevent air leakage and maintain system efficiency.
Technical & Performance Notes
- The narrow throat (2.25″) introduces a higher velocity and potential pressure drop — ensure system design accommodates this without excessive noise or restriction.
- Galvanized steel and hot-dip galvanization protect against rusting in indoor HVAC environments.
- At 30 gauge thickness, the boot is moderately rigid but should be handled carefully to avoid dents or deformation during installation.
- Proper alignment with the duct end and register face is critical to avoid turbulence or inefficiency in airflow.
- Use of sealing materials (foil tape or mastic) on seams and edges is strongly recommended to preserve system performance.
Specifications
| Weight | 0.500000 |
|---|---|
| Length (inches) | 14 |
| Width (inches) | 2 |
| Height (inches) | 2 |
| Item Type | Register Boots |
| Brand | Lukjan |
| Manufacturer | Lukjan Metal Products |
| MPN | RB102126 |
| Sub Type | End Register Boot |
| Diameter | 6 in |
| End Direction | Straight |
| Material | Galvanized Steel |
| Material Thickness | 30 ga |
| Overall Width | 2 in |
| Item Returns | This item can be returned |